<LOGO>
FM Transmitter Measurement Report
Created: 2025-06-27 18-44-47
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
89.40 MHz 5/5, 57 dBuV ISKELMA
Pilot RDS Phase Difference
6.4 kHz 2.6 kHz -85 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
8 kHz 64 kHz 18942 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,1 dBr 5,32 dBr 6,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"ISKELMA " 62AD 9 (Varied) 1 0 1 1 --:--
RT
-
AF EON
89.4, 92.5, 95.0, 100.1 MHz -
FM Scope Max at: 64 kHz MIN: 8 kHz % above 76 kHz: 0,0000 Acquired: 2025/06/27 18.43.43 Total samples: 18942 Equivalent time: 0:15:47 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000 4000
FM Scope MAX: 6,5 dBr MIN: 3,1 dBr AVE: 5,32 dBr % above 12,2 dBr: 0,0 Last value: 5,9 dBr (2025/06/27 18.43.42) 18.30 18.32 18.34 18.36 18.38 18.40 18.42 0 2 4 6 Pm [dBr]